Espressif Systems /ESP32-H2 /PCNT /U2_STATUS

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as U2_STATUS

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0ZERO_MODE 0 (THRES1)THRES1 0 (THRES0)THRES0 0 (L_LIM)L_LIM 0 (H_LIM)H_LIM 0 (ZERO)ZERO

Description

PNCT UNIT2 status register

Fields

ZERO_MODE

The pulse counter status of PCNT_U%s corresponding to 0. 0: pulse counter decreases from positive to 0. 1: pulse counter increases from negative to 0. 2: pulse counter is negative. 3: pulse counter is positive.

THRES1

The latched value of thres1 event of PCNT_U%s when threshold event interrupt is valid. 1: the current pulse counter equals to thres1 and thres1 event is valid. 0: others

THRES0

The latched value of thres0 event of PCNT_U%s when threshold event interrupt is valid. 1: the current pulse counter equals to thres0 and thres0 event is valid. 0: others

L_LIM

The latched value of low limit event of PCNT_U%s when threshold event interrupt is valid. 1: the current pulse counter equals to thr_l_lim and low limit event is valid. 0: others

H_LIM

The latched value of high limit event of PCNT_U%s when threshold event interrupt is valid. 1: the current pulse counter equals to thr_h_lim and high limit event is valid. 0: others

ZERO

The latched value of zero threshold event of PCNT_U%s when threshold event interrupt is valid. 1: the current pulse counter equals to 0 and zero threshold event is valid. 0: others